A Few Insights About Air Circuit Breakers

Publish Time: Author: Site Editor Visit: 314

Air circuit breaker is an electrical appliance with protection function. In the event of a severe overload or short circuit fault, the air circuit breaker will disconnect. In normal use, we rarely manually disconnect the air circuit breaker.

Next, we will briefly talk about the little knowledge of air circuit breakers.

We all know that ACB will be equipped with a controller, so what are the models of the controller?

 

The controller model have

Mic2.0/2.0A/2.0E

Mic5.0/5.0A/5.0E/5.0P/5.0H

Mic6.0/6.0A/6.0E/6.0P/6.0H

Mic7.0A/7.0P/7.0H

So what's the difference between Mic2.0, Mic5.0, Mic6.0 and Mic7.0?

 

 

Mic2.0

Mic5.0

Mic6.0

Mic7.0

Current protection

long time

+ instantaneous

long time

+ short time

+ instantaneous

long time

+ short time

+ instantaneous

+ earth fault

long time

+ short time

+ instantaneous

+ earth leakage up to 3200A

 

So what's the difference between A,E,P and H?

 

Type

Measurements and programmable protection

Basic type

◆ Basic long delay, short delay, instantaneous protection, ground fault protection

◆ Long delay warning function

A: ammeter

 I 1 , I2 , I3 , IN, Iearth-fault, Iearth-leakage and maximeter for these measurements

 fault indications

 settings in amperes and in seconds.

E: Energy

incorporates all the rms measurements of MicroLogic A, plus voltage, power factor, power and energy metering measurements

 calculates the current demand value

 "Quickview" function for the automatic cyclical display of the most useful values (as standard or by selection).

 

P: A + power meter + programmable protection

 

 measurements of V, A, W, VAR, VA, Wh, VARh, VAh, Hz, Vpeak, Apeak, power factor and maximeters and minimeters

 IDMTL long-time protection, minimum and maximum voltage and frequency, voltage  and current imbalance, phase sequence, reverse power

 load shedding and reconnection depending on power or current

 measurements of interrupted currents, differentiated fault indications, maintenance indications, event histories and time-stamping, etc.

H: P + harmonics

 

 power quality: fundamentals, distortion, amplitude and phase of harmonics up to the 31st order

 waveform capture after fault, alarm or on request

 enhanced alarm programming: thresholds and actions.

 

 

 

The above is a brief introduction to the control unit of the air circuit breaker, if you want to know more, you can visit our home page or contact us.